HANNA HI801 เครื่องสเปกโตรโฟโตมิเตอร์ เครื่องวัดการดูดกลืนแสง

รหัสสินค้า : SH001

ราคา

120,000.00 THB

จำนวนที่จะซื้อ
ราคารวม 120,000.00 THB

สินค้าไม่เพียงพอ

สินค้าหมด



HI801 Iris Visible Spectrophotometer

     The HI801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.


Customize your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.

  • iris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more.
  • Results are consistent and accurate regardless of throughput with the high quality and uniquely designed optics system.
  • Customization options include multiple cuvette shapes and sizes, custom calibration curves, and methods.

Details

iris spectrophotometer

Superior design for superior results.

iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.

With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.

 

No need for measurement conversions.

Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.

 

The convenience of pre-programmed methods with the option to expand.

iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive.

Customize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers.

Easily access your favorite methods directly from the home screen to save time.

Built in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.

iris spectrophotometer

iris spectrophotometer cuvette

 

Change sample size easily.

With our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.

 

RoundVialSquareHI801_Cuvette-Insert-RoundHI801_Cuvette-Insert-VialHI801 cuvette square


Worry free replacements.

iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.


HI801 Lamp 

Designed for dynamic environments.

iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.

HI801 battery

 

 

iris spectrophotometer

Quality data without the hassle.

Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.

 

Menu navigation that makes sense.

Quickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.

 

Sort and share your data.

Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you.

iris spectrophotometer

All of your important information is easily visible.

With a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.

 

Zero resistance with a capacitive touch pad.

Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.

Parameters



ParameterRangeResolutionAccuracy (at 25 °C)MethodWavelengthReagent CodeAbsorbance0.000 to 3.000 Abs0.001 Abs5 mAbs at 0.000-0.500 Abs

1% at 0.500-3.000 Abs

   Alkalinity0 to 500 mg/L (as CaCO3 )1 mg/L±5 mg/L ±5% of readingColorimetric Method610 nmHI775-26Alkalinity, Marine0 to 300 mg/L (as CaCO3 )1 mg/L±5 mg/L ±5% of readingColorimetric Method610 nmHI755-26Aluminum0.00 to 1.00 mg/L (as Al3+)0.01 mg/L±0.04 mg/L ±4% of readingAdaptation of the aluminon method.525 nmHI93712-01Ammonia, Low Range0.00 to 3.00 mg/L (as NH3 -N)0.01 mg/L±0.04 mg/L ±4% of readingAdaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.420 nm HI93700-01Ammonia, Medium Range 0.00 to10.00 mg/L (as NH3 -N)0.01 mg/L±0.05 mg/L ±5% of readingAdaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method420 nm HI93715-01Ammonia, High Range 0.0 to 100.0 mg/L (as NH3 -N)0.1 mg/L±0.5 mg/L ±5% of readingAdaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method420 nm HI93733-01Bromine 0.00 to 8.00 mg/L (as Br2 )0.01 mg/L±0.08 mg/L ±3% of readingAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method525 nm HI93716-01Calcium0 to 400 mg/L (as Ca2+) 1 mg/L ±10 mg/L ±5% of reading Adaptation of the Oxalate method466nm  HI937521-01Calcium, Marine 200 to 600 mg/L (as Ca2+) 1 mg/L ±6% of reading Adaptation of the Zincon method610 nm  HI758-26Chemical Oxygen Demand, Low Range0 to 150 mg/L (as O2 )1 mg/L±5 mg/L or ±4% of readingAdaptation of the USEPA 410.4420 nmHI93754A-25Chemical Oxygen Demand, Medium Range0 to 1500 mg/L (as O2 )1 mg/L±15 mg/L or ±4% of readingAdaptation of the USEPA 410.4610 nmHI93754B-25Chemical Oxygen Demand, High Range0 to 15000 mg/L (as O2 )1 mg/L±150 mg/L or ±2% of readingAdaptation of the USEPA 410.4610 nmHI93754C-25Chloride 0.0 to 20.0 mg/L (as Cl) 0.1 mg/L ±0.5 mg/L ±6% of reading Adaptation of the mercury(II) thiocyanate method466 nm  HI93753-01Chlorine Dioxide 0.00 to 2.00 mg/L (as ClO2 ) 0.01 mg/L ±0.10 mg/L ±5% of reading Adaptation of the Chlorophenol Red method575 nm  HI93738-01Chlorine, Free Ultra Low Range 0.000 to 0.500 mg/L (as Cl2 ) 0.001 mg/ ±0.020 mg/L ±3% of reading Adaptation of the Standard Method 4500-Cl G525 nm  HI95762-01Chlorine, Free Low Range 0.00 to 5.00 mg/L (as Cl2) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93701-01Chlorine, Free High Range 0.00 to 10.00 mg/L (as Cl2)0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93734-01Chlorine, Total Ultra Low Range 0.000 to 0.500 mg/L (as Cl2 ) 0.001 mg/L ±0.020 mg/L ±3% of reading Adaptation of the EPA recommended Method 330.5 525 nm HI95761-01Chlorine, Total Low Range 0.00 to 5.00 mg/L (as Cl2) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93711-01Chlorine, Total High Range 0.00 to 10.00 mg/L (as Cl2) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93734-01Chlorine, Total Ultra High Range 0 to 500 mg/L (as Cl2 ) 1 mg/L ±3 mg/L ±3% of reading Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl525 nm  HI95771-01Chromium (VI), Low Range 0 to 300 µg/L (as Cr(VI)) 1 µg/L ±10 µg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method525 nm  HI93749-01Chromium (VI), High Range 0 to 1000 µg/L (as Cr(VI)) 1 µg/L ±5 µg/L ±4% of reading at 25 °C Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method 525 nm HI93723-01Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method420 nm  Copper, Low Range 0.000 to 1.500 mg/L (as Cu) 0.001 mg/L ±0.010 mg/L ±5% of reading Adaptation of the EPA method575 nm  HI95747-01Copper, High Range 0.00 to 5.00 mg/L (as Cu) 0.01 mg/L ±0.02 mg/L ±4% of reading Adaptation of the EPA method 575 nm HI93702-01Cyanide 0.000 to 0.200 mg/L (as CN-) 0.001 mg/L ±0.005 mg/L ±3% of reading Pyridine-Pyrazalone 610 nm HI93714-01Cyanuric Acid 0 to 100 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading Adaptation of the turbidimetric method 525 nm HI93722-01Fluoride, Low Range 0.00 to 2.00 mg/L (as F) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method575 nm  HI93729-01Fluoride, High Range 0.0 to 20.0 mg/L (as F) 0.1 mg/L ±0.5 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method 575 nm HI93739-01Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO3 ) 0.01 mg/L ±0.11 mg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method 525 nm HI93720-01Hardness, Magensium 0.00 to 2.00 mg/L (CaCO3 ) 0.01 mg/L ±0.11 mg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method 525 nm HI93719-01Hardness, Total Low Range 0 to 250 mg/L (as CaCO3 ) 1 mg/L ±5 mg/L ±4% of reading Adaptation of the EPA recommended method 130.1466 nm  HI93735-00Hardness, Total Medium Range  200 to 500 mg/L (as CaCO3 ) 1 mg/L ±7 mg/L ±3% of reading Adaptation of the EPA recommended method 130.1466 nm  HI93735-01Hardness, Total High Range 400 to 750 mg/L (as CaCO3 ) 1 mg/L ±10 mg/L ±2% of reading Adaptation of the EPA recommended method 130.1 466 nm HI93735-02Hydrazine 0 to 400 µg/L (as N2H4 ) 1 µg/L ±4% of full scale reading Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method 466 nm HI93704-01Iodine 0.0 to 12.5 mg/L (as I2 ) 0.1 mg/L ±0.1 mg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method 525 nm HI93718-01Iron, Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading Adaptation of the TPTZ Method 575 nm HI93746-01Iron, High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters 525 nm HI93721-01Magnesium 0 to 150 mg/L (as Mg2+) 1 mg/L ±5 mg/L ±3% of reading Adaptation of the Calmagite method 466 nm HI937520-01Manganese, Low Range 0 to 300 µg/L (as Mn) 1 µg/L ±10 µg/L ±3% of reading Adaptation of the PAN Method 575 nm HI93748-01Manganese, High Range 0.0 to 20.0 mg/L (as Mn) 0.1 mg/L ±0.2 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method525 nm  HI93709-01Maple Syrup 0.00 to 100.00 %T 0.01 %T ±3% of reading Direct measure 560 nm HI93703-57Molybdenum 0.0 to 40.0 mg/L (as Mo6+) 0.1 mg/L ±0.3 mg/L ±5% of reading Adaptation of the mercaptoacetic acid method 420 nmHI93730-01Nickel, Low Range 0.000 to 1.000 mg/L (as Ni) 0.001 mg/L ±0.010 mg/L ±7% of reading Adaptation of the PAN method 575 nm HI93740-01Nickel, High Range 0.00 to 7.00 g/L (as Ni) 0.01 g/L ±0.07g/L ±4% of reading Adaptation of the photometric method 575 nm HI93726-01Nitrate 0.0 to 30.0 mg/L (as NO3 - N) 0.1 mg/L ±0.5 mg/L ±10% of reading Adaptation of the cadmium reduction method525 nm  HI93728-01Nitrate, Chromotropic Acid 0.0 to 30.0 mg/L (as N03--N)0.1 mg/L±1.0 mg/L or ±3% of reading Chromotropic acid method 410 nm HI93766-50Nitrite, Marine Ultra Low Range 0 to 200 µg/L (as N02 -N) 1 µg/L ±10 µg/L ±4% of reading Adaptation of the EPA Diazotization method 354.1 466 nm HI764-25Nitrite, Low Range 0 to 600 µg/L (as NO2 -N) 1 µg/L ±20 µg/L ±4% of reading Adaptation of the EPA Diazotization method 354.1 466 nmHI93707-01Nitrite, High Range 0 to 150 mg/L (as NO2-) 1 mg/L ±4 mg/L ±4% of reading Adaptation of the Ferrous Sulfate method 575 nm HI93708-01Nitrogen, Total Low Range 0.0 to 25.0 mg/L (as N) 0.1 mg/L ±1.0 mg/L or ±5% of reading Chromotropic acid method 420 nm HI93767A-50Nitrogen, Total High Range 10 to 150 mg/L (as N) 1 mg/L ±3 mg/L or ±4% of reading Chromotropic acid method 420 nm HI93767B-50Oxygen, Dissolved 0.0 to 10.0 mg/L (as O2 ) 0.1 mg/L ±0.4 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method 420 nm HI93732-01Oxygen Scavengers (Carbohydrazide) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.01 mg/L ±0.02 mg/L ±3% of reading Adaptation of the iron reduction method 575 nm HI96773-01Oxygen Scavengers (Diethylhydroxylamine)(DEHA) 0 to 1000 µg/L (as DEHA) 1 µg/L ±5 µg/L ±5% of reading Adaptation of the iron reduction method 575 nm HI96773-01Oxygen Scavengers (Hydroquinone) 0.00 to 2.50 mg/L (as Hydroquinone) 0.01 mg/L ±0.04 mg/L ±3% of reading Adaptation of the iron reduction method 575 nm HI96773-01Oxygen Scavengers (Iso-ascorbic Acid) 0.00 to 4.50 mg/L (as Iso-ascorbic acid) 0.01 mg/L ±0.03 mg/L ±3 % of reading Adaptation of the iron reduction method 575 nm HI96773-01Ozone 0.00 to 2.00 mg/L (as O3 ) 0.01 mg/L ±0.02 mg/L ±3% of reading Colorimetric DPD Method 525 nm HI93757-01pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH Adaptation of the Phenol Red method 525 nm HI93710-01Phosphorus, Marine Ultra Low Range 0 to 200 µg/L (as P) 1 µg/L ±5 µg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method 610 nm HI736-25Phosphate, Low Range 0.00 to 2.50 mg/L (as PO4 3-) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the Ascorbic Acid method 610 nm HI93713-01Phosphate, High Range 0.0 to 30.0 mg/L (as PO4 3-) 0.1 mg/L ±1.0 mg/L ±4% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method 525 nm HI93717-01Phosphorous, Reactive Low Range0.00 to 1.60 mg/L (as P)0.01 mg/L±0.05 mg/L or ±4% of readingAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.610 nmHI93758A-50Phosphorous, Reactive High Range0.0 to 32.6 mg/L (as P)0.1 mg/L±0.5 mg/L or ±4% of readingAdaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method.420 nmHI93763A-50Phosphorous, Acid Hrdyolyzable0.00 to 1.60 mg/L (as P)0.01 mg/L±0.05 mg/L or ±5% of readingAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.610 nmHI93758B-50Phosphorous, Total Low Range0.00 to 1.15 mg/L (as P)0.01 mg/L±0.05 mg/L or ±6% of readingAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.610 nmHI93758C-50Phosphorous, Total High Range0.0 to 32.6 mg/L (as P)0.1 mg/L±0.5 mg/L or ±5% of readingAdaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method.420 nmHI93763B-50Potassium, Low Range 0.0 to 20.0 mg/L (as K) 0.1 mg/L ±2 mg/L ±7% of reading Adaptation of the Turbidimetric Tetraphenylborate method 466 nm HI93750-01Potassium, Medium Range 10 to 100 mg/L (as K) 1 mg/L ±10 mg/L ±7% of reading Adaptation of the Turbidimetric Tetraphenylborate method 466 nm HI93750-01Potassium, High Range 20 to 200 mg/L (as K) 1 mg/L ±20 mg/L ±7% of reading Adaptation of the Turbidimetric Tetraphenylborate method 466 nm HI93750-01Silica, Low Range 0.00 to 2.00 mg/L (as SiO2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method 610 nm HI93705-01Silica, High Range 0 to 200 mg/L (as SiO2 ) 1 mg/L ±1 mg/L ±5% of reading Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2 466 nm HI96770-01Silver 0.000 to 1.000 mg/L (as Ag) 0.001 mg/L ±0.020 mg/L ±5% of reading Adaptation of the PAN method 575 nm HI93737-01Sulfate 0 to 150 mg/L (as SO42-) 1 mg/L ±5 mg/L ±3% of reading Sulfate is precipitated with barium chloride crystals 466 nm HI93751-01Surfactants, Anionic 0.00 to 3.50 mg/L (as SDBS) 0.01 mg/L ±0.04 mg/L ±3% of reading Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS 610 nm HI95769-01Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method 575 nm HI93731-01

** Reagents for 50 tests.† Unless noted otherwise, all reagent codes ending with -01 are for 100 tests.

Visitors: 304,897